TECHNICAL DETAILS
MAGNETIC SYSTEM
The chain bounded to the external mechanism adhered to the glass via double-sided adhesive is manually pulled down either on the right side or left, thus, system is activated. This action rotates chain slot located within the external mechanism and activates the shaft, which bears a magnet on the end thereof connected to the lower gear system. The magnet magnetizes the corresponding magnet located within internal section of the glass and, forces the same to rotate. Via gear reducer system within the internal frame, pivot action of the magnet within the glass axially activates hexagonal shaft located 90degrees in vertical position. Hexagonal shaft, by spinning the pipe within slot thereof inserted into bearing pipe upfolds or lowers venetion blind strings maintained via metallic and plastic rings. Such movement of strings enable both axial and vertical action of venetion blind.

SHAFTED SYSTEM
The shaft is connected to the mechanism within the glass and, by protruding through the aperture that opens out at the bend of glass, fits on the external mechanism gear system. Via gear reducer system within the internal frame, pivot action of the magnet axially activates hexagonal shaft located 90degrees in vertical position. Hexagonal shaft, by spinning the pipe within slot thereof inserted into bearing pipe, upfolds or lowers venetion blind strings maintained via metallic and plastic rings. Such movement of strings enable both axial and vertical action of venetion blind.

 
 
 
 
 